View Issue Details

IDProjectCategoryView StatusLast Update
0000491T99X171.00 SKB EagleHWpublic2019-03-05 21:16
Reporter(SW) Jacky Chiang Assigned To(HW) Sean Chiang Due Date
PrioritynormalSeveritys2-severeReproducibilityhave not tried
Status closedResolutionfixed 
Summary0000491: ESD test
DescriptionESD test
TagsNo tags attached.
Attach Tags

Users monitoring this issue

User List (ALTech) SB Park , (ALTech) SY Yoon , (PM) Sheila Tu

Activities

(ALTech) SB Park

2019-02-28 09:47

developer   ~0001248

[1/29] SKB request to protect from static electricity. How many KV test are FXN at air and contact
         test. And What point does test at ESD test
[1/29] It will be discussed with HW engineer seperately. But it should be update here

(ALTech) SB Park

2019-02-28 09:49

developer   ~0001249

FXN answer
-----------------------------------------------------------
IEC standard :EN61000-4-2
Test level :Contact discharge +/- 4 KV
                  Air discharge +/- 8 KV

Issue History

Date Modified Username Field Change
2019-02-22 11:32 (SW) Jacky Chiang New Issue
2019-02-28 09:47 (ALTech) SB Park Note Added: 0001248
2019-02-28 09:49 (ALTech) SB Park Note Added: 0001249
2019-02-28 09:49 (ALTech) SB Park Assigned To => (HW) Sean Chiang
2019-02-28 09:49 (ALTech) SB Park Status new => assigned
2019-02-28 09:49 (ALTech) SB Park Issue Monitored: (ALTech) SB Park
2019-02-28 09:50 (ALTech) SB Park Issue Monitored: (ALTech) SY Yoon
2019-02-28 09:50 (ALTech) SB Park Issue Monitored: (PM) Sheila Tu
2019-03-05 21:16 (ALTech) SB Park Status assigned => closed
2019-03-05 21:16 (ALTech) SB Park Resolution open => fixed