View Issue Details
| ID | Project | Category | View Status | Date Submitted | Last Update |
|---|---|---|---|---|---|
| 0000491 | T99X171.00 SKB Eagle | HW | public | 2019-02-22 11:32 | 2019-03-05 21:16 |
| Reporter | (SW) Jacky Chiang | Assigned To | (HW) Sean Chiang | Due Date | |
| Priority | normal | Severity | s2-severe | Reproducibility | have not tried |
| Status | closed | Resolution | fixed | ||
| Summary | 0000491: ESD test | ||||
| Description | ESD test | ||||
| Tags | No tags attached. | ||||
| Attach Tags | |||||
| User List |
|
|---|
|
|
[1/29] SKB request to protect from static electricity. How many KV test are FXN at air and contact test. And What point does test at ESD test [1/29] It will be discussed with HW engineer seperately. But it should be update here |
|
|
FXN answer ----------------------------------------------------------- IEC standard :EN61000-4-2 Test level :Contact discharge +/- 4 KV Air discharge +/- 8 KV |
| Date Modified | Username | Field | Change |
|---|---|---|---|
| 2019-02-22 11:32 | (SW) Jacky Chiang | New Issue | |
| 2019-02-28 09:47 |
|
Note Added: 0001248 | |
| 2019-02-28 09:49 |
|
Note Added: 0001249 | |
| 2019-02-28 09:49 |
|
Assigned To | => (HW) Sean Chiang |
| 2019-02-28 09:49 |
|
Status | new => assigned |
| 2019-02-28 09:49 |
|
Issue Monitored: (ALTech) SB Park | |
| 2019-02-28 09:50 |
|
Issue Monitored: (ALTech) SY Yoon | |
| 2019-02-28 09:50 |
|
Issue Monitored: (PM) Sheila Tu | |
| 2019-03-05 21:16 |
|
Status | assigned => closed |
| 2019-03-05 21:16 |
|
Resolution | open => fixed |